Operation and control module
Operation and control module is designed for integration into mine set electrical equipment (compact stations and control stations) and start-protection apparatus with voltage up to 1140 V of alternate current and frequency 50 Hz, which functions as a remote control device for mining machines and mechanisms and controls machinery ground lead continuity.
The module can be designed in the following versions:
- OCM-01 — for integration into mine set electrical equipment;
- OCM-02 — for integration into mine start-protection apparatus.
Climatic version MCC (moderately cold climate) location category 5 according to State Standard 15150-69. Module electrical diagram is to prevent from:
- control loss in case of short circuit failure or wire breakage of operation and control circuit;
- automatic activation in case of short-term supply voltage rise up to 150% from the rated voltage.
Basic specifications:
Parameter | Value | |
OCM-01 | OCM-02 | |
Power supply voltage, V | 42 | 36 |
Supply network frequency, Hz | 50 | |
Rated wattage, W | 2 | |
Dimensions, mm (max) | 68x40x122 | 63x120x127 |
Maximum weight, kg | 0.35 | 0.5 |
Operational mode — continuous | S1 | |
Maximum permissible capacitance of operation and control circuits, mcF | 0.7 | |
Maximum resistance of testable ground lead, Om | 100 | |
Level and type of explosion protection | [Ex ib] l | |
Maximum voltage switched by alternate current actuating relay contacts, V | 60 | |
Minimum current switched by actuating relay contacts, A | 2 | |
Ingress protection rating | lP 30 | |
Ambient temperature, ° C | from — 10 to + 35 | |
Relative air humidity at the maximum temperature (35±2)° C, % | 98±2 | |
Maximum altitude above sea level, m | 1000 | |
Minimum average error-free running time, h | 10000 | |
Minimum average operating life, years | 6 | |
Examples of module order record
“Operation and control module OCU-01 TU BY 600175052.004-2005”;
“Operation and control module OCU-02 TU BY 600175052.004-2005”.
See also